Superior Liquid Cooling Systems
®
English v1.01
RP-1250
Users Manual
RP-1250
Users Manual
www.koolance.com
ISO
9001
Printed in Korea
Seitenansicht 0
1 2 3 4 5 6 ... 16 17

Inhaltsverzeichnis

Seite 1 - User’s Manual

Superior Liquid Cooling Systems®English v1.01RP-1250User’s ManualRP-1250User’s Manualwww.koolance.comISO 9001Printed in Korea

Seite 2 - User Manual

1213User ManualInstallationATX Pass-Through LeadThe ATX pass-through lead is responsible for sending the shut-down signal if any sensor reaches the pr

Seite 3 - Table of Contents

1415User ManualInstallationCooler & Tubing ConfigurationThere are a vast number of methods for configuring a liquid cooling system (serial, paral

Seite 4 - Chapter1

1617User ManualParallel LoopsParallel loops are normally used to help accommodate water blocks with significantly disproportionate flow restriction. T

Seite 5 - ◙ for 2

1819User ManualWith the connected outlet hose, roughly estimate the length you will need to your first cooler, and cut it.Cut the second hose with eno

Seite 6

2021User ManualFilling & MaintenanceOnce all the water blocks have been connected, the system can be filled with coolant. The fill port is located

Seite 7

2223User ManualFilling & MaintenanceWith normal use, Koolance’s liquid coolant should be replaced every 2-3 years. If it ever becomes contaminated

Seite 8

2425User Manual5. My system has boot-up problems, or does not turn on...Make sure the ATX wire lead is connected to “NO” (Normally Open) on the rear o

Seite 9 - Chapter2

26Limited WarrantyDisclaimerKoolance Incorporated (“Koolance”) warrants each new Koolance liquid-cooled system (“the system”), against defects in mate

Seite 10 - Temperature Sensor Placement

iUser ManualThis User Manual is updated regularly. Please be sure to check our support page for a newer version of this guide: www.koolance.com/suppor

Seite 11 - Fittings

iiiiiUser ManualTable of ContentsSystem Features 1Product Diagram ...

Seite 12 - Hose Lengths

iv1User Manual - Temperature Sensors (x3) - ATX Pass-Thru Wire - Mounting screws - ATX Jumper Wire - User ManualIncluded Hardwareflat-head screw

Seite 13 - Chapter3

23User ManualProduct DiagramReservoirReservoir & Pump - The coolant tank is transparent for easy liquid-level monitoring through the front window.

Seite 14 - Testing & Filling

45User ManualCAUTION: Generally, sensors report liquid temperature at the water block, which is typically 5-10°C (9-18°F) lower than the actual heat s

Seite 15 - Troubleshooting

67User Manual System FeaturesPUMP SETThe pump speed can be manually set from 1-10: PUMP(1-10) 7LV : Pump Speed LevelThe pump speed level wil

Seite 16

89User Manual System FeaturesThis page is intentionally left blank.The selected line will flash. Use ▼ and ▲ to navigate to other lines. Press ◙ to

Seite 17 - Disclaimer

1011User ManualPositioning the UnitThe cooling unit is designed to operate in one orientation. In other directions, the pump and reservoir may not ble