Koolance EXT-400SL-V2-R Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Hardware Koolance EXT-400SL-V2-R herunter. Koolance EXT-400SL-V2-R User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Protected by U.S. Patents 6,313,990; 6,664,627; 7,167,366; 7,295,436
Other Technology Pending U.S. & World-Wide Patents
Superior Liquid Cooling Systems
®
English v1.2
Exos-2 LX, Exos-2.5
Users Manual
Exos-2 LX, Exos-2.5
Users Manual
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - User’s Manual

Protected by U.S. Patents 6,313,990; 6,664,627; 7,167,366; 7,295,436 Other Technology Pending U.S. & World-Wide PatentsSuperior Liquid Cooling Sy

Seite 2 - User Manual

5User ManualLED Display PanelModesThe Exos-2 LX and Exos-2.5 offers seven display options. All are reached by continually pressing the SET button:1. T

Seite 3

6 IntroductionAlarm & Shutdown SettingsBy default, the Koolance audio alarm will sound if any sensor reaches 55ºC (131ºF). When the system alar

Seite 4 - Table of Contents

7User ManualChapter2Connecting Exos Systems

Seite 5 - Required Tools

8Positioning the ExosThe Exos is designed to operate in various locations, but it must run upright. Air fi ltration is not possible in all orientations

Seite 6 - Chapter1

9User ManualExternal Nozzles & Power CableCut the included 10mm (3/8”) tubing into two segments. You will need to connect each to the Exos’ rear n

Seite 7 - Advantages of Water Cooling

10 Connecting Exos SystemsConnecting the Slot AdapterThe Slot Adapter allows the Exos to connect with any ATX computer through an available card slo

Seite 8

11User ManualInstall the Slot Adapter into any available rear card slot in your computer.Screw the Slot Adapter in place as you would a normal device.

Seite 9 - Exos System Diagram

12 Connecting Exos SystemsPower ConnectionThe Exos-2 LX and Exos-2.5 requires approximately 20-30W from any standard ATX power supply. Since it is a

Seite 10 - LED Display Panel

13User ManualATX Power SwitchThe ATX “pass through” lead is responsible for shutting off your computer if sensor channel #1 reaches 3ºC (5ºF) above t

Seite 11

14Series SystemsFor systems with only CPU coolers, a simple series loop will provide the best performance. Connecting Exos Systems1010101010CPU Bloc

Seite 12 - Chapter2

iUser ManualThis User Manual is updated regularly. Please be sure to check our support page for a newer version of this guide: www.koolance.com/suppor

Seite 13 - Positioning the Exos

15User ManualThe maximum number of coolers allowed in a system will depend upon your specifi c thermal requirements and hose confi guration. It is not u

Seite 14

16Nozzles are designed to attach tightly. If you need to remove a hose for any reason, it may not pull off easily, even after unscrewing the compressi

Seite 15 - Connecting the Slot Adapter

17User ManualHose LengthsBefore installing your liquid coolers, appropriate lengths of tubing must be cut to connect each device. It is generally easi

Seite 16 - Installing the Slot Adapter

18Continue connecting all of your coolers in the system until there are no longer any open tube ends.Liquid CoolersYou should now install the liquid c

Seite 17 - Power Connection

19User ManualChapter3Filling & MaintenanceWARNING: The Exos-2 LX and Exos-2.5’s powerful single pump can not be run “dry” for any period of time.

Seite 18 - ATX Power Switch

20Once all of the coolers have been connected, the system can be fi lled with coolant. The refi ll plug is located on top of the reservoir. Remove the l

Seite 19

21User ManualAllow the pumps to run for about 1-5 minutes. If your pump has a speed control option, it should be run at the lowest setting during this

Seite 20

22Filling & MaintenanceUnder normal circumstances, the liquid coolant does not require replacement. However, if it becomes contaminated, unclear,

Seite 21 - Disconnecting Hoses

23User ManualWe hope your Koolance system will provide you with years of reliable cooling performance. To help avoid unnecessary RMA issues, we have p

Seite 22 - Hose Lengths

24be malfunctioning. Please visit our support web page for more information.Verify that the pump is operating (see Troubleshooting #1), and that liqui

Seite 23 - Liquid Coolers

iiWARNING: The Koolance liquid & coolant pack contain chemicals which may be harmful or fatal if swallowed. KEEP THIS AND ALL DANGEROUS CHEMICALS

Seite 24 - Chapter3

25User Manual8. The LED Display Panel shows 5 - 0 or 5 - 5...5 - 0 (“S - O”): Sensor open. This indicates a temperature sensor can not be detected for

Seite 25 - Testing & Filling

26Limited WarrantyDisclaimerKoolance Incorporated (“Koolance”) warrants each new Koolance liquid-cooled system (“the system”), against defects in mate

Seite 26

www.koolance.comISO 9001Printed in Korea

Seite 27

iiiUser ManualTable of ContentsIntroduction 1Exos System Diagram ...

Seite 28 - Troubleshooting

iv Exos Series Systems: - External Power Cable - Slot Adapter - Rubber foot pads - ATX power jumper wire - user manual - shutoff nozzles (select

Seite 29

1User ManualChapter1Introduction

Seite 30

2 Congratulations on your purchase of a Koolance system!As the most sophisticated product of its kind, Koolance offers many unique features found now

Seite 31 - Disclaimer

3User ManualThe heart of a liquid cooling system is the pump. This device pushes liquid through each cooler and into the heat exchanger. Koolance syst

Seite 32 - Printed in Korea

4 IntroductionExos System DiagramReservoir & PumpRadiator Cooling FansReservoir Refi ll PlugCoolant InletPower ConnectionLED Display PanelReserv

Kommentare zu diesen Handbüchern

Keine Kommentare