This menu affects when the built-in audio alarm will sound. Upon entering the
alarm menu, the temperature delta-t value will flash. Press or to adjust this
value. Press to accept and return to the previous menu.
ALARM SET
(TEMP SET) ± 5C
In the above example, the alarm will sound if the temperature exceeds a 5°C
difference (+ or -) from the chiller’s currently active temperature sensor (see “TEMP
SET”). The maximum delta-T setting range for the alarm is 49°C.
The regular audio alarm is a repeating beep. If a steady alarm tone is heard, this
indicates the relay has also been triggered (see “RELAY SET”).
NOTE: The alarm temperature must be at least 1°C (1-2°F) lower than the relay
temperature. If an alarm temperature can not be increased, first increase the relay
temperature. Likewise, if a relay temperature can not be decreased, first decrease
the alarm temperature.
RELAY SET
Rear terminals are provided for a temperature-
configurable relay. Wires can be connected as
normally-open (NO), or normally-closed (NC),
labeled below the terminals.
To adjust the relay trigger point, enter the “RELAY
SET” menu. Press or to adjust this value.
Press to accept and return to the previous
menu.
RELAY SET
(TEMP SET) ± 40C
In the above example, the relay will trigger if the temperature exceeds a 40°C
difference (+ or -) from the chiller’s currently active temperature sensor (see “TEMP
SET”). The maximum delta-T setting range for the relay is 50°C.
NOTE: The relay temperature must be at least 1°C (1-2°F) higher than the alarm
temperature. If an alarm temperature can not be increased, first increase the relay
temperature. Likewise, if a relay temperature can not be decreased, first decrease
the alarm temperature.
ALARM SET PUMP SET
The pump speed can be manually set from 1 (lowest) to 10 (highest):
PUMP(1-10) 7LV : Pump Speed Level
The pump speed level will flash. Press
or to adjust. Press to return to the
previous menu.
DISPLAY SET
The display settings configure which values you wish to appear on the front display
and how they are shown:
DISPLAY
FIXED CYCLIC : Show 2 fixed values or cycle multiple values
The first option, “FIXED”, will flash. Press or to change between these
options. Press to configure one of the selections, or press to exit. If “FIXED”
is selected, two lines will be shown:
LIQ SET 20C : First line display option
EXT TEMP 21.4C : Second line display option
The first line will flash. Press or to change what this line will display:
LIQ SET : (Field varies) Shows current active sensor and user set-point
AMB TEMP : Shows ambient air temperature
LIQ TEMP : Shows reservoir liquid temperature
EXT TEMP : Shows external sensor temperature (if connected)
FAN : Shows condenser fan RPM
PUMP : Shows pump impeller RPM
FLOW : Shows liquid flow rate through the unit
Press to move to line 2, and similarly use or to choose what will be
displayed on the second line. Press again to exit.
WARNING: The cooling system’s pump can not be run dry for any
period of time. Never power-on the chiller without sufficient liquid in
the reservoir. Dry-running (and thereby damaging the pump) is not
covered under the Koolance product warranty.
!